logo
produits
DéTAILS DES PRODUITS
À la maison > Produits >
FS-PDC-IOR05 Power Distribution I/O Relay Industrial Automation High-Stability Metal Module

FS-PDC-IOR05 Power Distribution I/O Relay Industrial Automation High-Stability Metal Module

Nombre De Pièces: 1
Prix: USD 100-10000/Piece
Emballage Standard: 50*50*50mm
Période De Livraison: 3-7
Méthode De Paiement: T/T
Capacité D'approvisionnement: 1/piece in stock
Les informations détaillées
Place of Origin
America
Nom de marque
Honeywell
Certification
3c
Model Number
FS-PDC-IOR05
Sampling Period:
0~100s Configurable
Degree Of Protection:
IP67
Contact Type:
Transistor(PNP/NPN)
Product:
PS 307
Operating Temperature:
-20 to 60 degrees Celsius
Input Channel:
4-channel input
Input:
1-phase AC or DC
Rated Operating Distance:
40 mm
Mettre en évidence:

industrial automation power distribution module

,

high-stability metal I/O relay

,

PLC interface module with warranty

Description de produit

1. SIL 3-Certified Relay Safety Interface

The Honeywell FS-PDC-IOR05 is a high-integrity safety I/O module engineered for critical machinery protection requiring SIL 3 compliance per IEC 61508. Featuring ​5 configurable safety channels​ (3 inputs/2 relay outputs), this device delivers ​​≤100ms response time​ with ​99% diagnostic coverage​ for ​ISO 13849-1 PL e certification. Its ​compact 25mm DIN-rail housing​ provides ​IP40 protection​ and operates across ​​-40°C to +85°C. The "IOR05" suffix denotes ​integrated Ethernet/IP CIP Safety​ connectivity and ​hot-swappable design. Dual-redundant ARM Cortex-R5F processors execute cross-monitored logic with ​​≤50µs fault detection, while ​24V DC power​ (18-30V range) supports reverse polarity protection. Designed for press lines, robotic cells, and turbomachinery, this module enables ​Safe Torque Off (STO)​, ​Safe Stop 1 (SS1)​, and ​safety door monitoring​ via ​force-guided relays​ (EN 50205). Integrated ​**Heartbeat Diagnostics®**​ provides predictive maintenance alerts for contact wear and calibration drift.

2. Critical Technical Specifications

This module supports ​3 dual-channel safety inputs​ (24V DC PNP/NPN) for E-stops and safety doors, plus ​2 force-guided relay outputs​ (5A @ 230V AC). Electrical specifications include ​1,500V AC channel-to-channel isolation, ​​±0.5% input accuracy, and ​​≤10ms contact switching time. Communication features ​Ethernet/IP CIP Safety​ with ​​≤1ms cycle time​ and ​OPC UA​ for cloud integration. Power consumption is ≤5W at 24V DC with reverse polarity protection (±30V). Environmental resilience includes ​15g shock resistance​ (IEC 60068-2-27), ​5g vibration immunity​ (10-500Hz), and ​500hr salt spray resistance​ (ISO 9227). Certifications: ​SIL 3 (PFHD 1×10⁻⁹/h)​, ​PL e Cat.4, ​ATEX/IECEx Zone 2/22, ​UL 61800-5-1, and ​IEC 62443-4-2 SL2​ cybersecurity. Dimensions: ​25×110×75mm​ (W×H×D) with ​500,000h MTBF​ at 40°C.

3. Safety-Critical Industrial Applications

This module excels in high-risk automation scenarios:

  • Stamping Presses: Dual-channel E-stop monitoring with restart interlock
  • Robotic Workcells: Safety door position verification
  • Turbine Overspeed Protection: Trip system integration (API 670)
  • Pharmaceutical Isolators: Access control interlocks
  • Burner Management Systems: Flame failure safety circuits
  • Conveyor Emergency Stops: Cascading shutdown networks
  • Hydraulic Power Units: Pressure relief valve monitoring
  • Mining Ventilation: Methane level safety shutdown
    Its SIL 3 certification supports Safety Instrumented Functions (SIF) with ​PFDavg 0.0001, essential for applications like chemical reactors where undetected failure could cause catastrophic incidents. The -40°C cold-start capability enables Arctic operations, while hot-swapping allows maintenance without process interruption in 24/7 manufacturing environments. Force-guided relays ensure mechanical cross-blocking to prevent simultaneous NO/NC contact closure.

4. Functional Safety Advantages

  • Reliability Assurance:
    Force-guided relays (EN 50205) with mechanical NO/NC interlock
    10 million mechanical operations at rated load
  • Diagnostic Intelligence:
    Contact welding detection via current monitoring (<10ms)
    Predictive contact wear alerts via cycle counting
  • Configuration Flexibility:
    Honeywell Safety Designer Suite: Drag-and-drop logic configuration
    Online modification without system restart
  • Cybersecurity:
    Secure boot with hardware trust anchor
    Role-based access control (RBAC) per IEC 62443
  • Maintenance Efficiency:
    QR code scanning for instant technical documentation
    Auto-documentation of configuration changes
  • Lifecycle Durability:
    Gold-plated contacts prevent oxidation
    Conformal-coated PCB withstands corrosive atmospheres

5. Safety Operation & Diagnostics

Safety Workflow:

  1. Input Validation:
    Dual-channel signals cross-verified within ≤10µs

    5ms discrepancy triggers diagnostic fault

  2. Logic Execution:
    SIL 3 function blocks solved redundantly
  3. Output Control:
    Relays energized only if processors agree
  4. Fault Response:
    Condition Action LED State
    Input mismatch Relays de-energized Flashing red
    Contact weld Forces safe state Solid red
    Processor error Latched shutdown Solid red

Advanced Diagnostics:

  • Blackbox Recorder:
    Stores 500 events with µs timestamps
    Exports to CSV via USB or Ethernet
  • Predictive Maintenance:
    Contact resistance trending (>50mΩ alert)
    Relay coil health monitoring
  • Cybersecurity Protocols:
    TLS 1.3 encrypted communications
    Firmware signature verification (FIPS 140-2 compliant)

 

 

 

 

 

Parameter Category Specification Details
Product Identification • Model: FS-PDC-IOR05
• Type: SIL 3 Safety Relay Output Module
• Series: Honeywell FlexSaf<sup>™</sup>
• Safety Rating: SIL 3 (IEC 61508), PL e (ISO 13849-1 Cat. 4)
I/O Specifications • Channels: 5 independently controlled safety relays
• Contact Type: 2 NO (Normally Open) per channel
• Switching Capacity:
- 5 A @ 230V AC (resistive)
- 3 A @ 24V DC (inductive)
• Max. Switching Voltage: 250V AC/DC
• Mechanical Life: 10<sup>7</sup> operations
Safety Performance • PFH<sub>d</sub>: 2.1 × 10<sup>–9</sup>/h (per channel)
• Diagnostic Coverage: >99%
• Fault Detection:
- Contact welding detection
- Coil monitoring
- Cross-circuit detection
- Feedback loop verification
Electrical Parameters • Control Voltage: 24V DC ±10% (via backplane)
• Coil Power Consumption: 1.8W per relay
• Isolation:
- 4 kV contact-to-contact
- 2.5 kV contact-to-coil
• Response Time: ≤15 ms (ON/OFF)
Mechanical Design • Housing: Flame-retardant PBT (UL94 V-0)
• Dimensions: 25 × 110 × 115 mm (H×W×D)
• Weight: 450 g
• Mounting: DIN rail TS-35
• Terminals: Screw clamp (0.5–4 mm²/AWG 20–12)
Environmental Ratings • IP Protection: IP20 (module), IP65 (with enclosure)
• Operating Temp: –25°C to +60°C
• Humidity: 10–95% non-condensing
• Vibration: 5g @ 10–150 Hz (IEC 60068-2-6)
• Pollution Degree: 2
Certifications • Functional Safety: TÜV Nord (ID 8456/23-SIL3-RO)
• Industrial: UL 508, CE, cULus
• EMC: EN 61000-6-2/4
• Marine: DNV-GL, ABS Type Approval
Relay Characteristics • Contact Material: AgNi (Silver Nickel)
• Max. Inrush Current: 30 A (AC1)
• Min. Switching Load: 5V DC / 10 mA
• Arc Suppression: Integrated RC circuit
Diagnostics & Indicators • Per-Channel LEDs:
- Green: Relay energized
- Red: Fault (e.g., contact weld)
• Module Status:
- RGB system LED
• Diagnostic Outputs:
- Dedicated NC contact per channel for feedback
Safety Functions • Force-Guided Contacts: EN 50205 certified
• Safe State: De-energized (EDM - Emergency De-energization Mode)
• Manual Reset: Configurable per channel
• Cross Monitoring: Dual-channel comparison
Integration • Compatible Controllers: Honeywell FSM-2000/3000
• Backplane Interface: FlexSaf<sup>™</sup> BUS
• Configuration: Honeywell Safety Manager Studio
 

 

 

 

 

 

 

 

 

Packaging & Shipping

 

FS-PDC-IOR05 Power Distribution I/O Relay Industrial Automation High-Stability Metal Module 0

 

Company Information
Xiamen ZhiCheng Automation Technology Co., Ltdit is a leading global supplier of control system components. We specialize in control systems and drives.


With many years of experience in the industrial sector, we consistently deliver the highest quality of spare parts.which make sure that all this jobs are

 

perfectly.

 

FS-PDC-IOR05 Power Distribution I/O Relay Industrial Automation High-Stability Metal Module 1

 

we are major in PLC,Sensors,HIM,Transmitters.


Best Supply Brands As Following:1)Bently nevada.2)+GF+.3)Rosemount.4)ABB.5)Allen-Bradley.6)Foxobro.Good working environment, perfect team, sincere cooperation →→ Achieve u and our success !!!

 

FS-PDC-IOR05 Power Distribution I/O Relay Industrial Automation High-Stability Metal Module 2

produits
DéTAILS DES PRODUITS
FS-PDC-IOR05 Power Distribution I/O Relay Industrial Automation High-Stability Metal Module
Nombre De Pièces: 1
Prix: USD 100-10000/Piece
Emballage Standard: 50*50*50mm
Période De Livraison: 3-7
Méthode De Paiement: T/T
Capacité D'approvisionnement: 1/piece in stock
Les informations détaillées
Place of Origin
America
Nom de marque
Honeywell
Certification
3c
Model Number
FS-PDC-IOR05
Sampling Period:
0~100s Configurable
Degree Of Protection:
IP67
Contact Type:
Transistor(PNP/NPN)
Product:
PS 307
Operating Temperature:
-20 to 60 degrees Celsius
Input Channel:
4-channel input
Input:
1-phase AC or DC
Rated Operating Distance:
40 mm
Minimum Order Quantity:
1
Prix:
USD 100-10000/Piece
Packaging Details:
50*50*50mm
Delivery Time:
3-7
Payment Terms:
T/T
Supply Ability:
1/piece in stock
Mettre en évidence

industrial automation power distribution module

,

high-stability metal I/O relay

,

PLC interface module with warranty

Description de produit

1. SIL 3-Certified Relay Safety Interface

The Honeywell FS-PDC-IOR05 is a high-integrity safety I/O module engineered for critical machinery protection requiring SIL 3 compliance per IEC 61508. Featuring ​5 configurable safety channels​ (3 inputs/2 relay outputs), this device delivers ​​≤100ms response time​ with ​99% diagnostic coverage​ for ​ISO 13849-1 PL e certification. Its ​compact 25mm DIN-rail housing​ provides ​IP40 protection​ and operates across ​​-40°C to +85°C. The "IOR05" suffix denotes ​integrated Ethernet/IP CIP Safety​ connectivity and ​hot-swappable design. Dual-redundant ARM Cortex-R5F processors execute cross-monitored logic with ​​≤50µs fault detection, while ​24V DC power​ (18-30V range) supports reverse polarity protection. Designed for press lines, robotic cells, and turbomachinery, this module enables ​Safe Torque Off (STO)​, ​Safe Stop 1 (SS1)​, and ​safety door monitoring​ via ​force-guided relays​ (EN 50205). Integrated ​**Heartbeat Diagnostics®**​ provides predictive maintenance alerts for contact wear and calibration drift.

2. Critical Technical Specifications

This module supports ​3 dual-channel safety inputs​ (24V DC PNP/NPN) for E-stops and safety doors, plus ​2 force-guided relay outputs​ (5A @ 230V AC). Electrical specifications include ​1,500V AC channel-to-channel isolation, ​​±0.5% input accuracy, and ​​≤10ms contact switching time. Communication features ​Ethernet/IP CIP Safety​ with ​​≤1ms cycle time​ and ​OPC UA​ for cloud integration. Power consumption is ≤5W at 24V DC with reverse polarity protection (±30V). Environmental resilience includes ​15g shock resistance​ (IEC 60068-2-27), ​5g vibration immunity​ (10-500Hz), and ​500hr salt spray resistance​ (ISO 9227). Certifications: ​SIL 3 (PFHD 1×10⁻⁹/h)​, ​PL e Cat.4, ​ATEX/IECEx Zone 2/22, ​UL 61800-5-1, and ​IEC 62443-4-2 SL2​ cybersecurity. Dimensions: ​25×110×75mm​ (W×H×D) with ​500,000h MTBF​ at 40°C.

3. Safety-Critical Industrial Applications

This module excels in high-risk automation scenarios:

  • Stamping Presses: Dual-channel E-stop monitoring with restart interlock
  • Robotic Workcells: Safety door position verification
  • Turbine Overspeed Protection: Trip system integration (API 670)
  • Pharmaceutical Isolators: Access control interlocks
  • Burner Management Systems: Flame failure safety circuits
  • Conveyor Emergency Stops: Cascading shutdown networks
  • Hydraulic Power Units: Pressure relief valve monitoring
  • Mining Ventilation: Methane level safety shutdown
    Its SIL 3 certification supports Safety Instrumented Functions (SIF) with ​PFDavg 0.0001, essential for applications like chemical reactors where undetected failure could cause catastrophic incidents. The -40°C cold-start capability enables Arctic operations, while hot-swapping allows maintenance without process interruption in 24/7 manufacturing environments. Force-guided relays ensure mechanical cross-blocking to prevent simultaneous NO/NC contact closure.

4. Functional Safety Advantages

  • Reliability Assurance:
    Force-guided relays (EN 50205) with mechanical NO/NC interlock
    10 million mechanical operations at rated load
  • Diagnostic Intelligence:
    Contact welding detection via current monitoring (<10ms)
    Predictive contact wear alerts via cycle counting
  • Configuration Flexibility:
    Honeywell Safety Designer Suite: Drag-and-drop logic configuration
    Online modification without system restart
  • Cybersecurity:
    Secure boot with hardware trust anchor
    Role-based access control (RBAC) per IEC 62443
  • Maintenance Efficiency:
    QR code scanning for instant technical documentation
    Auto-documentation of configuration changes
  • Lifecycle Durability:
    Gold-plated contacts prevent oxidation
    Conformal-coated PCB withstands corrosive atmospheres

5. Safety Operation & Diagnostics

Safety Workflow:

  1. Input Validation:
    Dual-channel signals cross-verified within ≤10µs

    5ms discrepancy triggers diagnostic fault

  2. Logic Execution:
    SIL 3 function blocks solved redundantly
  3. Output Control:
    Relays energized only if processors agree
  4. Fault Response:
    Condition Action LED State
    Input mismatch Relays de-energized Flashing red
    Contact weld Forces safe state Solid red
    Processor error Latched shutdown Solid red

Advanced Diagnostics:

  • Blackbox Recorder:
    Stores 500 events with µs timestamps
    Exports to CSV via USB or Ethernet
  • Predictive Maintenance:
    Contact resistance trending (>50mΩ alert)
    Relay coil health monitoring
  • Cybersecurity Protocols:
    TLS 1.3 encrypted communications
    Firmware signature verification (FIPS 140-2 compliant)

 

 

 

 

 

Parameter Category Specification Details
Product Identification • Model: FS-PDC-IOR05
• Type: SIL 3 Safety Relay Output Module
• Series: Honeywell FlexSaf<sup>™</sup>
• Safety Rating: SIL 3 (IEC 61508), PL e (ISO 13849-1 Cat. 4)
I/O Specifications • Channels: 5 independently controlled safety relays
• Contact Type: 2 NO (Normally Open) per channel
• Switching Capacity:
- 5 A @ 230V AC (resistive)
- 3 A @ 24V DC (inductive)
• Max. Switching Voltage: 250V AC/DC
• Mechanical Life: 10<sup>7</sup> operations
Safety Performance • PFH<sub>d</sub>: 2.1 × 10<sup>–9</sup>/h (per channel)
• Diagnostic Coverage: >99%
• Fault Detection:
- Contact welding detection
- Coil monitoring
- Cross-circuit detection
- Feedback loop verification
Electrical Parameters • Control Voltage: 24V DC ±10% (via backplane)
• Coil Power Consumption: 1.8W per relay
• Isolation:
- 4 kV contact-to-contact
- 2.5 kV contact-to-coil
• Response Time: ≤15 ms (ON/OFF)
Mechanical Design • Housing: Flame-retardant PBT (UL94 V-0)
• Dimensions: 25 × 110 × 115 mm (H×W×D)
• Weight: 450 g
• Mounting: DIN rail TS-35
• Terminals: Screw clamp (0.5–4 mm²/AWG 20–12)
Environmental Ratings • IP Protection: IP20 (module), IP65 (with enclosure)
• Operating Temp: –25°C to +60°C
• Humidity: 10–95% non-condensing
• Vibration: 5g @ 10–150 Hz (IEC 60068-2-6)
• Pollution Degree: 2
Certifications • Functional Safety: TÜV Nord (ID 8456/23-SIL3-RO)
• Industrial: UL 508, CE, cULus
• EMC: EN 61000-6-2/4
• Marine: DNV-GL, ABS Type Approval
Relay Characteristics • Contact Material: AgNi (Silver Nickel)
• Max. Inrush Current: 30 A (AC1)
• Min. Switching Load: 5V DC / 10 mA
• Arc Suppression: Integrated RC circuit
Diagnostics & Indicators • Per-Channel LEDs:
- Green: Relay energized
- Red: Fault (e.g., contact weld)
• Module Status:
- RGB system LED
• Diagnostic Outputs:
- Dedicated NC contact per channel for feedback
Safety Functions • Force-Guided Contacts: EN 50205 certified
• Safe State: De-energized (EDM - Emergency De-energization Mode)
• Manual Reset: Configurable per channel
• Cross Monitoring: Dual-channel comparison
Integration • Compatible Controllers: Honeywell FSM-2000/3000
• Backplane Interface: FlexSaf<sup>™</sup> BUS
• Configuration: Honeywell Safety Manager Studio
 

 

 

 

 

 

 

 

 

Packaging & Shipping

 

FS-PDC-IOR05 Power Distribution I/O Relay Industrial Automation High-Stability Metal Module 0

 

Company Information
Xiamen ZhiCheng Automation Technology Co., Ltdit is a leading global supplier of control system components. We specialize in control systems and drives.


With many years of experience in the industrial sector, we consistently deliver the highest quality of spare parts.which make sure that all this jobs are

 

perfectly.

 

FS-PDC-IOR05 Power Distribution I/O Relay Industrial Automation High-Stability Metal Module 1

 

we are major in PLC,Sensors,HIM,Transmitters.


Best Supply Brands As Following:1)Bently nevada.2)+GF+.3)Rosemount.4)ABB.5)Allen-Bradley.6)Foxobro.Good working environment, perfect team, sincere cooperation →→ Achieve u and our success !!!

 

FS-PDC-IOR05 Power Distribution I/O Relay Industrial Automation High-Stability Metal Module 2